Here is the initial concept for the “tiers/buckets” for NaaS @ various EOHHS locations:
Basic
- Professional Services Site Survey, Heat Map, Etc.
- 1 Circuit
- Layer 3 Switch (based on site survey)
- X number of APs (based on site survey)
- Security Appliance
Standard / Advanced
- Professional Services Site Survey, Heat Map, Etc.
- 2 Circuits
- Layer 3 Switch (based on site survey)
- X number of APs (based on site survey)
- Security Appliance
Critical Sites
- Professional Services Site Survey, Heat Map, Etc.
- 2+ Circuits (based on site requirements)
- Layer 3 HA Switches (based on site survey HA configuration may be implemented pending MDF/IDF distributions)
- 20-30% Overlapped X number of APs (based on site survey)
- HA Security Appliances
- 15 minute survivability with UPS
AP Model:
- MR46
Switch Options:
- MS225-48LP: 53-490 W max
- MS225-48FP: 54-882 W max
- Small stub comm closet that has less than 24 ports
- MS225-24P: 21-448 W ma
Security Appliance:
- Fortinet 60E
Latest Pricing Model
- 5 year minimum term
- 24 & 48 Port PoE switches will be provided — Number of APs per site will determined upon survey, and determine the appropriate switch
- WiFi Survey and Switch & WAP installs will be credited to offset charges — Figures below considered budgetary for this sample site
- Cabling is excluded